Replaced breaker still nothing. But dont bypass GFCI protection, thats just to determine if its a motor problem or outlet problem. But the moment the basket fills with water its like the pump just kicks down to barely running or humming at all. search, pool & drain cover safety Hello, Just bought a house with a pool in January. Hi Jodi, perhaps the rod is not threaded all the way into the base, or there may be debris under the rod, preventing it from going down fully. I was hoping that you can give me some advice. On attempting to open the pool, the motor started humming. If there is input power, the fuse may have blown. If the meter reads zero, and stays at zero the capacitor is bad. I believe there a water volume calculator, that can help us size the motor, the originally company who installed is not in business. Hi Douglas, it could be the capacitor, if youre lucky. Click OK to extend your time for an additional 0 minutes. Automatic reset is 60 minutes. Motor is connected to 220 volts and each phase consume 3.8 amps. Remove the pump and basket, then look for and remove any debris in the shaft. This year, I noticed at times that the flow rate on low speed is less than it was last year. Does anyone know what Im talking about and/or know how to repair? I am thinking it must be the age of the pump. If you download the owners manual on the Ecostar there is some further information about Drive Errors, and some things you can try, in the troubleshooting section, to verify the fault, and also lists the part number for the drive, if needed. I put a new power cord socket in the water proof box, which feeds power to the pump, I shined up the power cord plug pins), (power cord is about 2.5 ft of 12 Ga, not wet, not laying on the ground) What is the problem. Thanks. Hi Davy, However, when the filter is running for about 2-3 hours, the pressure increases to 20 psi, and the output water flow is minimal at best (extremely slow). We purchased a Hayward D.E Filter last summer. SOme pumps have an open bracket where you can see the shaft, but not Hayward. I currently have Hayward RS750CA and it starts leaking underneath. You could remove the filter grid completely from the tank (and clean well), start the pump without the grid assembly inside (removing most of the resistance) and see how the water flows. After trying every chemical under the sun and replacing the sand, I pulled the trigger and started from scratch. He did notice that there was de inside of the filter grids so prior to putting it back together we completely flushed each of the grids making sure to get all the de out from inside of them. Fans of space opera and world-building fantasies will find this first book in the series compelling, concluding with a powerful vision of world-changing gods and attempts to free Eden from its curse that conclude in a cliffhanger for future books to explore. Please advise ). The same thing happened to the first one. ), or the valves that are before the pump. The pump need not be completely air tight, but has to pull more water than air! It shouldnt be overheating, not in twenty seconds, but I suppose it could. On the return side, after the heater, the return valve should also move, with Spa Jets fully open and pool returns fully closed. You might be surprised by how many people neglect to check this area. It is a H400FDN series. Hi Mike, after backwashing a DE filter, you need to add DE filter powder again. Also inspect other wires in the back, look for any pinched wires, or wires touching each other. It looks old and Im thinking about replacing it. I purchased it June of 2018. A check valve could also be a solution, but a Drain King is different, they are used to pressure lines, for blowing out clogged drains usually, but also useful to pressurize the suction manifold to look for air leaks, or for priming a pump that has issues catching prime. Replace with the exact same MFD number, printed on the capacitor. 2. check the pump motor wiring, at the timeclock and the motor. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Air leaks are another source of priming issues. Another oddity is both failure are upon Spring re-opening,and the pumps ran flawlessly throughout each summer? Also will need to have clean pump basket and a clean pool filter, to ensure adequate flow rates. I have removed and tested the capacitor it appears OK I then removed the thermostat to try to access the shaft and turn it with a 7/17 wrench, but the protrusions on the casting and other spring mounted stuff appear to make it impossible to get a grip on the shaft. I shut the pump down the other night and it will not run. I have mud in my filter so I guess I have a underground broken pipe. better tool to use? Then there is often a switch or a timeclock that is wired in between the sub-panel and the pump. The correct replacement would be the AquaRite Main PCB (OEM) GLX-PCB-RITE. I would turn it off and it would hum and eventually start. I have an inground salt water pool with a spa and my flow rate was low so I cleaned out everything and replaced the filters and now the flow rate seems good with one problem. The pump is only one year old. the tubes are sealed at the end by the two seal plates. Yesterday I plugged it in to filter and where the plug goes into the 3 foot heavy duty extension it sparked smoked and created a small flame. It could also be a bad capacitor, which is like a battery, to start the motor. Hi Peter, I think you might be jumping the wrong terminals? Hi John, the cap for that motor is START CAPACITOR, 161-193 MFD (BC-161) we dont carry it, but easily found online. Any suggestions. It is only a 2-3 year old pump. If no power there, check the timer, if no power there, check the breaker, if no power there Is the main breaker in the house on? Any suggestions? },
I have a thermal switch on it,thank goodness or the motor would probably be fried. Not usually related to a tripped GFI, but I suppose they could be linked. Filter runs fine at first, but then eventually loses its umph and then the return becomes minimal. This is a salt pool not sure if that matters in the question. Cant find anything that jumps right out. Nothing is making any noise now and pump is not working at all. Step 2: Verify the accuracy of the salt readings (2700-3400 pm) with an independent test kit or by taking a water sample to your local pool store for testing. 3. pipe going into pump Theres no sound, when we hit the power switch no power. Then back to no pressure. Likewise, check if the motor is wired correctly for the available field supply voltage. When I turn on my pump it runs normal for 5 seconds thank it winds down then reverts back to normal speed. The pump has been running for 2 days. Hi Jim, yes it could be leaking, around the stem that sticks up thru the valve body and attaches to the handle. Check all wires and switches and connections in the back of the motor, look for anything loose or ant infested or broken connections. The error code will be cleared upon a valid data exchange between boards, If the limit string opens the heater shuts down and goes into lockout. I would guess this is what is happening, and if so your service company is either uneducated or dishonest. Now when we try to turn everything on the pump wont start at all and keeps tripping the breaker. Or a loose base part rattling? Went on to fill with water again & put on normal cycle and still was not getting a full prime. If so, put the meter on the terminals where to cord connects inside the motor and see if there is power there. After installing the new pump, priming it, it started running as normal, after a short time the new pump shut down and was very hot. Check the switches in the back of the motor, the centrifugal on the end of the shaft, and the stationary, mounted at 6 oclock, to look for any loose screws or insects, or mis-alignment. Turn on heater and see if you can narrow down the noise. Hi There I have a Hayward Super Pump VS pump. I just replaced the seal and all of the gaskets along with carefully cleaning the grooves that the gaskets rest in and greasing them thoroughly with Jacks. died and I put in the old repaired motor. Probably not cant think of another issue. Slide your main switch to the AUTO position. ), you have it primed full of water? One of those areas can be sealed up to stop the leak. If it does make a hum or buzz sound, it could be a bad capacitor, the black cylinder at 9 oclock, in the rear of the motor. Either a leaky valve in front of the pump, loose fitting threaded into pump, or loose pump lid/o-ring, or sometimes a loose drain plug, with no Teflon tape on it, and a missing plug o-ring these can all allow air to draw into the pump. The pump has been fine since installed, we started up he pool about 30 days ago no issues. Now when my sweeper comes on my waterfall feature from my spa does not turn off like it should and my sweeper moves slowly and in circles. Second thing is to see if the Motor Shaft Spins Freely, rust can develop which can bind up a motor. Likely not a problem with the pump itself. Ive done the reset and it still showing 4300. Hi David, yes! When I go to backwash the filter pump shuts down. The situation is either an air leak in FRONT of the pump, around the pump lid, the pipe coming into the pump, or leaky suction side valves. Hi, We had a pool installed last fall and we are still figuring things out. Power is always present at supply input. By following the steps listed below, the Aqua Rite can successfully be restored.To view this guide step by step on our website, visit:http://www.inyopools.com/HowToPage/how_to_troubleshoot_a_hayward_aqua_rite.aspx A visual tip-off is something that is dripping water when the pump is OFF, or that sprays water for half-a-second at the instant the pump shuts off, is drawing air in, when the pump is runnning. It could also be the centrifugal switch located in the rear of the motor, on the end of the shaft, check for looseness, broken spring or other damage. The Hayward Aqua Plus Automation System should have the capability to accommodate several T-Cell sizes. Also in reviewing the setup, the salt water panel box does not even turn on on low. I believe I checked everything and hoping its just the electric cord and the fact that it is corroded and loose and likely loosing electric current after it gets heated up a bit. the 4th wire, the high speed wire. No lights are coming on as if no power. Hi you are getting power inside the motor, on the terminal board? Compare to Hayward T-Cell-15 It worked fine for the first 2-3 years and then every time it needs to restart, it trips the breaker. My Hayward Pump Super shuts off and then starts then shuts off and then starts again. I wonder if the lines are clogged or a pipe is partially collapsed. I only rotated the one piece how can the screws not go right back in? In most cases, it means that your motor is on the way out. Wait for the relay to click (5 to 10 seconds). I have backwashed the filter and the water is clear. For over 2 months, lots of troubleshooting, actually RE-PIPED THE SECTION FROM POOL TO PUMP done by professionalpump still will not primedraws water, wont primeplayed with outflow and values, no primetook apart (my nemesis) Hayward Perflex DE filter, cleaned fingers, silicone on gaskets, put back (I have done this crappy job a hundred times so I am familiar with the process)no primefeel like draining the damn pool and junking the whole thing >:(. Hi BRian, nothing special no make sure the outlet TEST button is not popped or tripped? service center location, advanced also dont forget to connect the bare bonding wire, if you have one. On your filter (X-Stream and Voyager) there are two large wing nuts under the lid which secure the pressure gauge and air bleeder. (returns are the lines going back to the pool, returning) Some pools can operate successfully with fewer than the original pipes, I have worked on many pools with abandoned main drains or skimmers that stopped working. main drain and skimmer) to feed this thirsty pump. EC65 uses 6 lbs, and EC75 uses 9 lbs, but since DE is half as light as others a lb of DE powder is more than 2 cups of dry measure, its actually closer to 4 cups. The temperature of the pool water is too high or too low to operate. I noticed the on/off switch seemed loose and when I took of the end case, the male disconnect to the switch was burned out. Theory and practice | Find, read and cite all the research you need on ResearchGate Chapter 1: The Evil Emperor's Son. Hi Mike, it could be the start capacitor going, or it could be that one of the bearings is not quite perfectly flat, and if the shaft stops rotating at the right spot, it has trouble making the shaft turn, until bumped. Thanks, Ive checked out your blog and you had very good info for audience. To break the rust, you spin the shaft, or impeller. BLUE WORKS PCB Main Circuit Board Compatible with Hayward Goldline GLX-PCB-Main System Board Visit the BLUE WORKS Store 193 ratings $16999 FREE Returns Available at a lower price from other sellers that may not offer free Prime shipping. Any suggestions what it could be. are red velvet ants dangerous to dogs stone county, mississippi mugshots disney half marathon 2023 crooked house (2008 trailer) Likewise, it could be any other obstruction after the pump (partially clogged pipes, small pipe size, partially closed return valves) all of which will produce higher than normal filter pressure. 5 Changed the seal I took out the filter cartridge and hosed it down replaced, emptied all the baskets but still no change, only one of the jets is pushing out water, but barely. Do I need to clean filter? if the motor is generating too much heat, this temp sensor will trip and shut off the pump. Motors that are reversible always ship from the factory at 230V, and need to be manually switched to accept 115V. A pump that simply wont start is a frustrating problem. IE9 and older versions are not supported. Check all the power wires for tight fit and no corrosion. '' ''' - -- --- ---- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- In a Quirked world where most people have a superpower-like uniqueness to them, His is among the most dangerous. Even with the cells reverse polarity feature, the scale will still form on the plates. External bypass is out of adjustment. Step 5: Measure your cells polarity to ensure they meet system parameters. Oh, and prepare yourself, a new motor or pump may be needed soon. I checked the power to the timer and I have 120 v to L1 & L2 but timer not running & pump wont run when I turn pump on manually. If clogged, open the pump up, and ream out the impeller vanes with a flexible wire. A local motor shop could probably fix you up for $100, if you can remove the pump, and drive it to their shop. PDF | On Jan 1, 2009, Eduardo Keegan and others published Cognitive-behavior therapy. I open the plastic door, fill with water and sometimes need to do this several times in order for it to keep going. Thank you Packing Pool Putty or Silicone around the fitting is a good fix, replacing the fitting is a better fix. Hi there, I made the very unfortunate decision to rent my home to a friend. Automatic restart 2 minutes after error is corrected. Also make sure that the stationary switch copper tabs are not fused together, and that it is centered on the centrifugal switch. Another possible cause is that the impeller is clogged with very small debris. Motor wiring is pretty simple, green to ground and the other two wires, doesnt matter which one, go to terminals L1 and L2. Improper voltage wiring is the usual culprit for smoking pump motors. Hi Thomas, the fitting that goes into the pump, was it also replaced? Sometimes it hums but wont start and other times there is nothing. Hi Jeff, probably that sound is worn bearings (pumps dont have brushes). And check that incoming power matches the voltage for the motor, as the motor can be switched to accept 110V or 220V, see wiring diagram on motor label. Just replaced the sand and cleaned the fingers, replaced the o rings and have a psi of 15 and great suction. Just opened up the pool and the Hayward Super Pump worked just fine until we started vacuuming the bottom. We are headquartered in Valley Stream, New York, just outside of New Theory and practice | Find, read and cite all the research you need on ResearchGate We would like to show you a description here but the site wont allow us. Could be one of these. If so, put a damper under the pump, a piece of heavy rubber or a shim to stabilize the pump. Thanks in advance for any help you can provide, the pool should be done in the next few days and need to figure out this pump situation. Hi Leah, when the pump is barely pumping, the problem is either in front of the pump or after the pump. You can consult the flow charts for each model, to compare flow rates among two pumps, with a given (or assumed) level of resistance (feet of head). A lb of DE is by volume, equal to a 1 lb coffee can, or about 4 cups of dry measure. If your hose has union connections that are tightened to connect to the filter, you may try some Teflon tape on the valve threads, or may need a new hose assembly, if the union threads are damaged. If stuck from rust build-up, move the capacitor (located at 9 oclock) and/or the thermal regulator (located at 12 oclock), out of the way, so that you can fit a 7/16 open end wrench on the slotted part of the shaft, behind the centrifugal switch that is screwed onto the end of the shaft. This time around I purchased the t-3 cell model since my pool is below 15k gallons. I have a Hayward HeatPro model HP21104T. Check all the wire connections inside the motor on the terminal board, the 2 wires and the ground wire. Hi Dave, we are replacing a Hayward superpump 1.5 horsepower with the same pump. This time around I purchased the t-3 cell model since my pool is below 15k gallons. Remove the back of the motor and look for anything loose wires, switches, tabs. The pump is pretty hot. 6. Testing a Pool Pump's Capacitor If your pool pump is not starting, but instead gives a 'hum' or a 'nnngh!' They are higher voltage or whateverbut could that be the problem? New motor sounds like the thermal overload switch (located at 12 oclock in the rear of the motor) is shutting off the motor, which is usually not a good sign, and mostly means the pump is on its way out. Is it possible that the filter is the problem? Hi Christy, there may be a GFCI test button that popped, on an outlet below the breaker box, or on a light pole? Hi Tony, yes if the impeller spins freely then the shaft does too (unless you are unthreading the impeller from a stationary shaft) normally. Troubleshooting a Salt Chlorinator First, check power. Not sure whats wrong. Then sometimes with no rhyme or reason the pump shuts down and will not come back on until after I turn off and on all breakers. Since the pool is still being finished, the lines going to and from the pool are not installed yet so wanted to put water in there to test. To determine the cause of your noisy pump, investigate the following reasons: Theres no need to feel overwhelmed if your Hayward pool pump isnt functioning correctly. Capacitor or needs new motor?? ), 2) the pump lid o-ring (is it lubed? http://www.inyopools.com/blogSHOP at our online store! Seems impeller is not turning, does it turn both ways or one way? On traditional intermatic time clocks, you also have to make sure the timer dogs are tight, or they can slip, use pliers to tighten the nut tighter to avoid. If the pump runs air tight, but slowly drains out over an hour or so, that is usually a pressure side (after the impeller) air leak. Check the motor vent holes, (bottom front) to be sure they are not clogged. hayward super pump C48L2N134B1. All-In-One Sanitization We cannot get it going again. of and in " a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or : had first one their its new after but who not they have 25 The following steps will provide a guide on how to recalibrate a Hayward Aqua Rite. I checked the wiring, replaced the breaker, cleaned the pump impeller, motor vents are clean. Why is this happening? It is usually set to run at high rpm early morning and that is before sun hits it. Almost ordered a new pump but it really sounded good. Turn on the Drain King to pressurize all the way up to the pump, or to the filter valve, and whatever you see leaking water thats your air leak. voltage reachs the stationary switch. Incorrect sizing can cause multiple problems, including low water flow. This ONLY happens when I connect my vac hose. Maybe the breaker is loose on the bar, or perhaps insects shorting it. We have a sand filter and no pressure gage. We are headquartered in Valley Stream, New York, just outside of New Posted: (10 days ago) Posted: (5 days ago) Mountainside Fitness is located at 9375 E Bell Rd, Scottsdale, AZ 85260.Mountainside Fitness can be contacted at (480) 502-2096. dr myers ultrasound. The box is reading no water flow and psi is just above 0. If it is a union valve, cream also on the union nut. This is why we usually recommend a larger cell than the cell rating would suggest. That is the black cylinder in the rear of the motor, located at 9 oclock. If there is a little noise, check the motor capacitor, or look at the motor switches in the back, look for anything that looks or smells funny. HELP!!! Hi Renaud, many motors come wired to accept 230V, but are reversible to 115V. Are I on the right track? Occasionally, while running, it trips the breaker. I was wondering, I have four returns coming into one pipe to the pump basket. If thats not it, check the valves on the suction side (skimmer/main drain) to be sure they are not leaking air. Suggestions ? When the pool guy switched it, it worked very well for about a month with no issues at all. hayward blue essence troubleshooting. For a better experience, please enable JavaScript in your browser before proceeding. Any ideas? Changed lid gasket and plugs in basket still same issue. "@type": "ImageObject",
Clean Gasket (no bits of debris or de powder), 2. Capacitor is a battery in the back of the motor, at 9 oclock that assists in starting the motor, if the capacitor was weak, that may draw more amps from the breaker. I turned power off from breaker, emptied basket, used fingers to check for debris in impellers, did not find any. It would run fine. At a total loss here, any suggestions would be greatly appreciated. of and to in a is " for on that ) ( with was as it by be : 's are at this from you or i an he have ' not - which his will has but we they all their were can ; one also the dr myers ultrasound. This is my first pool. Is this a 2-speed pump, or variable speed pump? Look closely at the centrifugal switch on the rear of the shaft, to be sure its tight and is not missing parts (like the springs), engage the switch by hand (power off), to be sure that the stationary switch (located at 6 oclock) is disengaging, or the two copper tabs separate. Ill look up the Drain King, is that something like a check valve? But heaters? Other timers will have a different switch, but all should have someway to override. Nothing your husband did, hes safe to come out of the doghouse, lol. We tried opening the pool today when we plugged in the Hayward filter it keeps blowing the circuit breaker. I had my Hayward pool/spa installed about 4 years ago. Heaters often normally make such sounds, could also be debris laying on top of the burners. Check the incoming voltage to be sure that you are within the range of 110V-125V. Hi Frank, so it ran for weeks or more on 115V, when set to accept 230V, and then it started overheating, and then ran great for about a month, but now it makes no noise at all. Wait for the number to. I purchased a hayward powerflo matrix 1.5 pump and Proseries 21 Filter a week and a half ago. No matter where we move dial we have water coming out the back wash pipe. "publisher": {
All check ok. When I checked it again, the shaft (impellers) spin freely when tested by hand, but its not actually spinning when powered up? Air can enter pressure side if the water is not making it all the way to the top of the filter or chlorinator. replace the entire pump with exact replacement. But, that may not be it, if you say the shaft is getting stuck each time?
Bt Hub Lights,
Nulifestyle Union New Jersey,
Sims 4 Moonglow Lighting Mod,
Articles H